Interior walls can be bonded. Exterior walls should not be.

The difference is not the panel, it is what happens to water behind it. Indoors, adhesive is fine on a stable substrate. Outdoors, the panel needs a cavity it can drain.

Interior
Bonded to substrate
Exterior
Bracket and cavity
Format
3200 × 1600 mm
Joints
Set on drawing

Travertine look wall cladding is bonded directly to a flat, stable interior substrate, or fixed on brackets with a drained cavity on exterior walls. Panel format is 3200 × 1600 mm at 20 to 30 mm, and the joint layout is set on the shop drawing before casting.

Interior: bonded

On a plastered or boarded wall that is flat and sound, a cementitious adhesive bed is enough. The panel is heavy, so the adhesive has to be specified for the weight, and the substrate has to be checked for flatness: a 3.2 m panel will not bend to follow a hollow wall.

Exterior: bracket and cavity

Outside, the panel is carried on brackets with a drained and ventilated cavity behind it. Water that passes the joint runs down the membrane and out at the base. Sealing every joint instead turns the cavity into a reservoir, which is why open or baffled joints are the default on a ventilated facade.

ConditionMethodWatch for
Interior, flat substrateAdhesive bondSubstrate flatness; adhesive rated for the weight
Interior, uneven or hollowBracket and railBracket range against the deviation
Exterior, anyVentilated bracket systemCavity drainage, cavity barriers
Wet interiorBond plus tanking behindTanking continuity at the base

Where the joints land

With a 3.2 m panel, the joint pattern is a design decision rather than a consequence of the module. Align joints with door heads, ceiling lines and changes of plane, and keep the vertical joints off the centre of a narrow wall where a 1.6 m width would leave an awkward offcut.

Questions buyers ask

How is travertine cladding installed on an interior wall?
Usually bonded with a cementitious adhesive to a flat, stable substrate. Where the wall is out of tolerance, a bracket and rail system is used instead so the panel is set to line.
Can it be used in a corridor with trolley traffic?
Yes, with a filled face and a 25 mm panel. Protection during construction is the bigger risk than wear in service.
What thickness for a wall?
20 mm for bonded interior work; 20 to 25 mm for bracketed walls. Thicker panels are for floors and heavy wear.